Flink CDC产品常见问题之写hudi的时候报错如何解决

本文涉及的产品
实时计算 Flink 版,5000CU*H 3个月
简介: Flink CDC(Change Data Capture)是一个基于Apache Flink的实时数据变更捕获库,用于实现数据库的实时同步和变更流的处理;在本汇总中,我们组织了关于Flink CDC产品在实践中用户经常提出的问题及其解答,目的是辅助用户更好地理解和应用这一技术,优化实时数据处理流程。

问题一:Flink CDC里3.0支持MySQL到MySQL的动态同步嘛,有没有yaml配置文件样例?


Flink CDC里3.0支持MySQL到MySQL的动态同步嘛,有没有yaml配置文件样例?


参考回答:

Flink CDC 3.0支持MySQL到MySQL的动态同步。以下是一个示例的yaml配置文件:

# Flink CDC source configuration
source:
  type: mysql-cdc
  host: <MySQL source host>
  port: <MySQL source port>
  username: <MySQL source username>
  password: <MySQL source password>
  database-name: <MySQL source database name>
  table-name: <MySQL source table name>
  binlog-ignore-table: <MySQL binlog ignore table list>
  enable-timestamp-extractor: true
  with-column-mapping: true
  column-mapping:
    <column mapping definitions>
# Flink CDC sink configuration
sink:
  type: mysql-sink
  host: <MySQL sink host>
  port: <MySQL sink port>
  username: <MySQL sink username>
  password: <MySQL sink password>
  database-name: <MySQL sink database name>
  table-name: <MySQL sink table name>
  pre-sink-tasks:
    <pre-sink task configurations>

请将<MySQL source host><MySQL source port>等占位符替换为实际的MySQL源主机、端口等信息,并根据需要配置其他参数。


关于本问题的更多回答可点击原文查看:https://developer.aliyun.com/ask/590886


问题二:Flink CDC里 cdc端应该如何加参数可以忽略这个错误?


Flink CDC里The driver could not establish a secure connection to SQL Server by using Secure Sockets Layer (SSL) encryption. Error: "The server selected protocol version TLS10 is not accepted by client preferences [TLS13, TLS12]". sqlserver版本太低 不支持 tls1.2 1.3 cdc端应该如何加参数可以忽略这个错误?


参考回答:

通过报错的日志分析的原因:

Flink CDC(Change Data Capture)无法与 SQL Server 建立安全的 SSL 连接,因为 SQL Server 使用的是较低版本的 TLS(传输层安全协议),而 Flink CDC 客户端的偏好是使用 TLS1.2 或 TLS1.3。

解决方案:

您可以在 Flink CDC 客户端的配置中添加参数来忽略这个错误。但是,请注意,这将降低连接的安全性,因为您将绕过 SSL/TLS 的检查。以下是一个示例参数,可以在 Flink CDC 的连接配置中添加:

java

.option("ssl-handshake-mode", "legacy")

这将会使 Flink CDC 客户端使用旧版的 SSL 握手模式,以兼容较低版本的 TLS。

请注意,使用旧版握手模式可能会带来安全风险,因为它可能使您的应用程序容易受到某些已知的 SSL/TLS 攻击的影响。因此,如果可能的话,最好的解决方案是升级 SQL Server 到支持 TLS1.2 或 TLS1.3 的版本。


关于本问题的更多回答可点击原文查看:https://developer.aliyun.com/ask/590887


问题三:么基于 Flink CDC 3.0 构建 MySQL 到 Doris 的 任务啊?


Flink CDC里就是通过基于 Flink CDC 3.0 构建 MySQL 到 Doris 的 Streaming ELT 这种方式来提交任务 可以在yaml文件中设置重启策略和存储checkpoint嘛?类似下方截图


参考回答:

是的,你可以在Flink CDC任务的yaml文件中设置重启策略和存储checkpoint。

对于重启策略,你可以使用restart-strategy参数来指定。例如,你可以设置为fixed-delayno-restartsfailure-rate等。具体的值和含义可以参考Flink官方文档。

对于存储checkpoint,你可以使用state.backend参数来指定checkpoint的存储后端。例如,你可以设置为filesystemrocksdb等。同时,你还可以设置其他相关的参数,如state.checkpoints.dir(用于指定checkpoint目录),state.checkpoints.num-retained(用于指定保留的checkpoint数量)等。具体的值和含义可以参考Flink官方文档。


关于本问题的更多回答可点击原文查看:https://developer.aliyun.com/ask/590888


问题四:Flink CDC里flink 在watemark内数据乱序,对数据使用event_time重新排?


Flink CDC里flink 在watemark内数据乱序,会对数据使用event_time重新排序并输出嘛?


参考回答:

在Apache Flink的流处理中,当接收到的数据存在乱序(out-of-order)时,特别是在使用了event-time语义的情况下,Flink确实会根据event_time对这些乱序数据进行重新排序。 watermark机制是用来处理乱序事件的核心组成部分。

具体来说:

  1. Event Time:在Flink中,event time指的是事件实际发生的时间戳,它通常由事件自身携带。
  2. Watermarks:水印(Watermark)是一种衡量事件时间进度的概念,它代表了到目前为止系统认为不会再有更早时间戳的事件到达的一个时间点。一旦水印时间戳推进到了某个窗口的结束时间,Flink就会触发对该窗口内数据的处理,即使还有晚到但时间戳早于水印时间戳的事件。
  3. 乱序处理:当乱序事件(即事件时间戳小于当前水印时间戳)到达时,它们会被放入状态后缓存起来,直到相应的窗口触发计算。这样,即使在watermark之内存在乱序数据,最终基于event_time窗口的结果仍然是正确的,因为Flink会等待足够长的时间(由watermark策略决定)来处理那些可能稍晚到达但属于同一窗口的乱序事件。


关于本问题的更多回答可点击原文查看:https://developer.aliyun.com/ask/590889


问题五:Flink CDC里flinkcdc写hudi的时候这个错误怎么弄?


Flink CDC里flinkcdc写hudi的时候这个错误怎么弄? own Source)

at org.apache.hadoop.hdfs.DFSOutputStream.addBlock(DFSOutputStream.java:1082)

at org.apache.hadoop.hdfs.DataStreamer.locateFollowingBlock(DataStreamer.java:1898)

at org.apache.hadoop.hdfs.DataStreamer.nextBlockOutputStream(DataStreamer.java:1700)

at org.apache.hadoop.hdfs.DataStreamer.run(DataStreamer.java:707)

81261 [mini-cluster-io-thread-3] INFO org.apache.flink.runtime.rpc.akka.AkkaRpcService - Stopping Akka RPC service.

81314 [flink-metrics-8] INFO org.apache.flink.runtime.rpc.akka.AkkaRpcService - Stopping Akka RPC service.

81314 [flink-metrics-8] INFO org.apache.flink.runtime.rpc.akka.AkkaRpcService - Stopped Akka RPC service.

81322 [flink-akka.actor.default-dispatcher-5] INFO org.apache.flink.runtime.blob.PermanentBlobCache - Shutting down BLOB cache

81324 [flink-akka.actor.default-dispatcher-5] INFO org.apache.flink.runtime.blob.TransientBlobCache - Shutting down BLOB cache

81328 [flink-akka.actor.default-dispatcher-5] INFO org.apache.flink.runtime.blob.BlobServer - Stopped BLOB server at 0.0.0.0:57196

81332 [flink-akka.actor.default-dispatcher-5] INFO org.apache.flink.runtime.rpc.akka.AkkaRpcService - Stopped Akka RPC service.

81332 [ForkJoinPool.commonPool-worker-4] WARN org.apache.flink.client.program.PerJobMiniClusterFactory - Shutdown of MiniCluster failed.

org.apache.flink.runtime.rpc.akka.exceptions.AkkaRpcException: Could not start RpcEndpoint jobmanager_3.

at org.apache.flink.runtime.rpc.akka.AkkaRpcActor$StoppedState.start(AkkaRpcActor.java:629)

at org.apache.flink.runtime.rpc.akka.AkkaRpcActor.handleControlMessage(AkkaRpcActor.java:185)

at akka.japi.pf.UnitCaseStatement.apply(CaseStatements.scala:24)

at akka.japi.pf.UnitCaseStatement.apply(CaseStatements.scala:20)

at scala.PartialFunction.applyOrElse(PartialFunction.scala:123)

at scala.PartialFunction.applyOrElse$(PartialFunction.scala:122)

at akka.japi.pf.UnitCaseStatement.applyOrElse(CaseStatements.scala:20)

at scala.PartialFunction$OrElse.applyOrElse(PartialFunction.scala:171)

at scala.PartialFunction$OrElse.applyOrElse(PartialFunction.scala:172)

at akka.actor.Actor.aroundReceive(Actor.scala:537)

at akka.actor.Actor.aroundReceive$(Actor.scala:535)

at akka.actor.AbstractActor.aroundReceive(AbstractActor.scala:220)

at akka.actor.ActorCell.receiveMessage$$$capture(ActorCell.scala:580)

at akka.actor.ActorCell.receiveMessage(ActorCell.scala)

at akka.actor.ActorCell.invoke(ActorCell.scala:548)

at akka.dispatch.Mailbox.processMailbox(Mailbox.scala:270)

at akka.dispatch.Mailbox.run(Mailbox.scala:231)

at akka.dispatch.Mailbox.exec(Mailbox.scala:243)

at java.util.concurrent.ForkJoinTask.doExec$$$capture(ForkJoinTask.java:289)

at java.util.concurrent.ForkJoinTask.doExec(ForkJoinTask.java)

at java.util.concurrent.ForkJoinPool$WorkQueue.runTask(ForkJoinPool.java:1067)

at java.util.concurrent.ForkJoinPool.runWorker(ForkJoinPool.java:1703)

at java.util.concurrent.ForkJoinWorkerThread.run(ForkJoinWorkerThread.java:172)

Caused by: org.apache.flink.runtime.jobmaster.JobMasterException: Could not start the JobMaster.

at org.apache.flink.runtime.jobmaster.JobMaster.onStart(JobMaster.java:391)

at org.apache.flink.runtime.rpc.RpcEndpoint.internalCallOnStart(RpcEndpoint.java:181)

at org.apache.flink.runtime.rpc.akka.AkkaRpcActor$StoppedState.lambda$start$0(AkkaRpcActor.java:624)

at org.apache.flink.runtime.concurrent.akka.ClassLoadingUtils.runWithContextClassLoader(ClassLoadingUtils.java:68)

at org.apache.flink.runtime.rpc.akka.AkkaRpcActor$StoppedState.start(AkkaRpcActor.java:623)

... 22 more

Caused by: org.apache.flink.util.FlinkRuntimeException: Failed to start the operator coordinators

at org.apache.flink.runtime.scheduler.DefaultOperatorCoordinatorHandler.startAllOperatorCoordinators(DefaultOperatorCoordinatorHandler.java:90)

at org.apache.flink.runtime.scheduler.SchedulerBase.startScheduling(SchedulerBase.java:585)

at org.apache.flink.runtime.jobmaster.JobMaster.startScheduling(JobMaster.java:965)

at org.apache.flink.runtime.jobmaster.JobMaster.startJobExecution(JobMaster.java:882)

at org.apache.flink.runtime.jobmaster.JobMaster.onStart(JobMaster.java:389)

... 26 more

Caused by: org.apache.hadoop.ipc.RemoteException(java.io.IOException): File /test/dept/.hoodie/hoodie.properties could only be written to 0 of the 1 minReplication nodes. There are 3 datanode(s) running and 3 node(s) are excluded in this operation.

at org.apache.hadoop.hdfs.server.blockmanagement.BlockManager.chooseTarget4NewBlock(BlockManager.java:2276)


参考回答:

这个错误是由于Hadoop在尝试将文件写入HDFS时,无法在所有指定的数据节点上进行复制。这可能是由于以下原因:

  1. 数据节点不可用或宕机。
  2. HDFS的副本因子设置过低,导致无法在所有节点上存储足够的副本。
  3. HDFS的磁盘空间不足。

要解决这个问题,你可以尝试以下方法:

  1. 检查数据节点的状态,确保它们都正常运行并且没有宕机。
  2. 增加HDFS的副本因子,以增加数据的冗余度。你可以在hdfs-site.xml文件中设置dfs.replication参数。
  3. 清理HDFS上的磁盘空间,以确保有足够的空间来存储新的数据块。


关于本问题的更多回答可点击原文查看:https://developer.aliyun.com/ask/590890

相关实践学习
基于Hologres轻松玩转一站式实时仓库
本场景介绍如何利用阿里云MaxCompute、实时计算Flink和交互式分析服务Hologres开发离线、实时数据融合分析的数据大屏应用。
Linux入门到精通
本套课程是从入门开始的Linux学习课程,适合初学者阅读。由浅入深案例丰富,通俗易懂。主要涉及基础的系统操作以及工作中常用的各种服务软件的应用、部署和优化。即使是零基础的学员,只要能够坚持把所有章节都学完,也一定会受益匪浅。
相关文章
|
3天前
|
监控 关系型数据库 MySQL
Flink CDC MySQL同步MySQL错误记录
在使用Flink CDC同步MySQL数据时,常见的错误包括连接错误、权限错误、表结构变化、数据类型不匹配、主键冲突和
34 16
zdl
|
1月前
|
消息中间件 运维 大数据
大数据实时计算产品的对比测评:实时计算Flink版 VS 自建Flink集群
本文介绍了实时计算Flink版与自建Flink集群的对比,涵盖部署成本、性能表现、易用性和企业级能力等方面。实时计算Flink版作为全托管服务,显著降低了运维成本,提供了强大的集成能力和弹性扩展,特别适合中小型团队和业务波动大的场景。文中还提出了改进建议,并探讨了与其他产品的联动可能性。总结指出,实时计算Flink版在简化运维、降低成本和提升易用性方面表现出色,是大数据实时计算的优选方案。
zdl
157 56
|
1月前
|
消息中间件 资源调度 关系型数据库
如何在Flink on YARN环境中配置Debezium CDC 3.0,以实现实时捕获数据库变更事件并将其传输到Flink进行处理
本文介绍了如何在Flink on YARN环境中配置Debezium CDC 3.0,以实现实时捕获数据库变更事件并将其传输到Flink进行处理。主要内容包括安装Debezium、配置Kafka Connect、创建Flink任务以及启动任务的具体步骤,为构建实时数据管道提供了详细指导。
87 9
|
1月前
|
SQL 运维 数据可视化
阿里云实时计算Flink版产品体验测评
阿里云实时计算Flink基于Apache Flink构建,提供一站式实时大数据分析平台,支持端到端亚秒级实时数据分析,适用于实时大屏、实时报表、实时ETL和风控监测等场景,具备高性价比、开发效率、运维管理和企业安全等优势。
|
2月前
|
数据可视化 大数据 数据处理
评测报告:实时计算Flink版产品体验
实时计算Flink版提供了丰富的文档和产品引导,帮助初学者快速上手。其强大的实时数据处理能力和多数据源支持,满足了大部分业务需求。但在高级功能、性能优化和用户界面方面仍有改进空间。建议增加更多自定义处理函数、数据可视化工具,并优化用户界面,增强社区互动,以提升整体用户体验和竞争力。
45 2
|
3月前
|
算法 API Apache
Flink CDC:新一代实时数据集成框架
本文源自阿里云实时计算团队 Apache Flink Committer 任庆盛在 Apache Asia CommunityOverCode 2024 的分享,涵盖 Flink CDC 的概念、版本历程、内部实现及社区未来规划。Flink CDC 是一种基于数据库日志的 CDC 技术实现的数据集成框架,能高效完成全量和增量数据的实时同步。自 2020 年以来,Flink CDC 经过多次迭代,已成为功能强大的实时数据集成工具,支持多种数据库和数据湖仓系统。未来将进一步扩展生态并提升稳定性。
687 2
Flink CDC:新一代实时数据集成框架
|
2月前
|
运维 数据处理 Apache
数据实时计算产品对比测评报告:阿里云实时计算Flink版
数据实时计算产品对比测评报告:阿里云实时计算Flink版
|
3月前
|
消息中间件 canal 数据采集
Flink CDC 在货拉拉的落地与实践
陈政羽在Apache Asia Community Over Code 2024上分享了《货拉拉在Flink CDC生产实践落地》。文章介绍了货拉拉业务背景、技术选型及其在实时数据采集中的挑战与解决方案,详细阐述了Flink CDC的技术优势及在稳定性、兼容性等方面的应用成果。通过实际案例展示了Flink CDC在提升数据采集效率、降低延迟等方面的显著成效,并展望了未来发展方向。
584 14
Flink CDC 在货拉拉的落地与实践
|
2月前
|
SQL 运维 大数据
大数据实时计算产品的对比测评
在使用多种Flink实时计算产品后,我发现Flink凭借其流批一体的优势,在实时数据处理领域表现出色。它不仅支持复杂的窗口机制与事件时间处理,还具备高效的数据吞吐能力和精准的状态管理,确保数据处理既快又准。此外,Flink提供了多样化的编程接口和运维工具,简化了开发流程,但在界面友好度上还有提升空间。针对企业级应用,Flink展现了高可用性和安全性,不过价格因素可能影响小型企业的采纳决策。未来可进一步优化文档和自动化调优工具,以提升用户体验。
141 0
|
2月前
|
SQL 运维 数据管理
在对比其他Flink实时计算产品
在对比其他Flink实时计算产品

相关产品

  • 实时计算 Flink版