开发者社区> 问答> 正文

请大神们帮小白分析一个mysql挂掉原因

160911 05:32:28 mysqld_safe Number of processes running now: 0
160911 05:32:28 mysqld_safe mysqld restarted
160911  5:32:35 [Note] Plugin 'FEDERATED' is disabled.
160911  5:32:36 InnoDB: The InnoDB memory heap is disabled
160911  5:32:36 InnoDB: Mutexes and rw_locks use GCC atomic builtins
160911  5:32:36 InnoDB: Compressed tables use zlib 1.2.3
160911  5:32:36 InnoDB: Using Linux native AIO
160911  5:32:36 InnoDB: Initializing buffer pool, size = 128.0M
InnoDB: mmap(137363456 bytes) failed; errno 12
160911  5:32:36 InnoDB: Completed initialization of buffer pool
160911  5:32:36 InnoDB: Fatal error: cannot allocate memory for the buffer pool
160911  5:32:36 [ERROR] Plugin 'InnoDB' init function returned error.
160911  5:32:36 [ERROR] Plugin 'InnoDB' registration as a STORAGE ENGINE failed.
160911  5:32:36 [ERROR] Unknown/unsupported storage engine: InnoDB
160911  5:32:36 [ERROR] Aborting

160911  5:32:36 [Note] /alidata/server/mysql/bin/mysqld: Shutdown complete

160911 05:32:36 mysqld_safe mysqld from pid file /alidata/server/mysql/data/iZ28jy75s3vZ.pid ended

展开
收起
ia、 2016-09-11 05:58:02 4274 0
2 条回答
写回答
取消 提交回答
  • ECS配置太低了   mysql 占用的资源还是挺多的。换RDS或者升级配置吧
    2016-09-11 10:35:58
    赞同 展开评论 打赏
  • 旺旺:nectar2。
    楼主您好,

    抱歉给您带来不便。

    cannot allocate memory for the buffer pool <<-- 从这句话的意思理解,可能是您当前的系统内存不足,可能导致mysql进程运行异常。

    请问您当前的ECS,购买的内存是多少的呢,1GB?
    2016-09-11 10:28:16
    赞同 展开评论 打赏