Project network redundant , Vmware virtualization, Dell VRTX P2V - Part 1 (General Network)

简介:

项目需求:

安装DellVRTX硬件,并连接到客户的生产网络,同时建立虚拟机实现客户RODC P2V的要求。

 

阶段一,安装DELLVRTX硬件,并完成下面的需求:

1. Dell Enclosure and Blades

-              Mountingof Enclosure to rack

-              Ensureeach blade server has the components installed

a)            2x CPU

b)            64GB RAM

c)            2 x 300GBSAS

-              Ensureenclosure has a total of 15x 900GB SAS hard disk

-              Connectall power cables to enclosure

-              Systempower up successfully

2.            Configurationof Enclosure, Blades, Storage and network switches

-              ActivateEnclosure CMC license and configure IP address for CMC

-              ConfigureEnclosure 2x switch module

-              Connectnetwork cable from enclosure to existing network switches

-              Configure2x Blade server with iDRAC license and configure IP address for iDRAC

-              ConfigureBlade server with RAID-1 configuration

-              ConfigureStorage with 2 arrays

Array 01               900GBx 6            RAID-5

Array 02               900GBx 7            RAIID-5

Global Hot-Spare             900GBx 2           

 

其实这些都是体力活,包含上导轨,安装CPU内存,那么需要注意的是:

如何internal的网卡映射到对应的服务器上

如何把对应Array分配给对应的服务器上

如何设置ArrayCMC控制台中

如何设置CMC硬件的Raid

如何映射KVM键盘鼠标DVD分配给对应的服务器

CMC中如何配置iDRAC

 

要完成这些,首先要进行客户网络的分析:

wKiom1czLtmQeKLjAADc6ROJk0o335.png

综述,其实对于大部分比较有钱的企业都会选取这样的网络架构,机会所有的设备都是双冗余的;只要这样连接完毕大部分都是可以用的,但是如果才能使其最优化确实大有文章可以探寻

 

问题一,在核心交换机上用了HSRP同时大部分人会采取冗余的接法,那么会有spanning-tree的产生;在这种情况下,如果才能使数据流更好的通过经过对应的交换机到达目的地?

答:首先我们用这样一个拓扑图来说明(其实在大部分的公司都是采用这个拓扑的)

wKiom1czLuyC4sZGAABdAvkDdSw385.png

分析1我们把vlan10 配置为STPRootCore1;这样在Core1Core2 Edgesw1上就形成了一个环路,此时应该是在edgesw1Fa0/2口为抑制端口,数据是通过Gi1/0/1向上通过FW1的对应端口上去的。这是正常情况。(没有网络中断和线路短线的情况下)。


如果,Link1断掉了,由于我们设置了HSRPtrack功能,由于我们设置了vlan 10的生成树的根桥,那么生成树肯定是在的,只是在Link1断掉后,没有了环路,生成树不起作用;那么BPDU的变更发出,Fa0/2会开启,那么数据流量会通过Core2,在绕到FW1上,情况如下图:

wKioL1czL_LSnh2AAABalOnhfG8323.png

如果,Core1完全坏掉了,那么整个左边全部坏掉,所有的流量都是从右边走,原因是,Core1坏掉了,stp不起作用了数据从core2走,同时FW上的HA会自动的让FW2作为Active,那么数据直接转发。


如果,FW1Core1LAN链路坏掉了(下面部分都是好的),那么数据会先从Core1走,然后由于HA的作用FW2会成为Active,那么Core2上的LAN会成为数据导入流,因为在LANMAC地址为成为FW2口上,所以数据会从Core1Core2,然后由FW2对应的LAN出去

 

 

所以企业网中,这种方式是最合理的,下面看具体的配置命令:

Core 1上(成为vlan的根桥,设置HSRP的优先级为主,跟踪下联端口):

interface Vlan10

 ip address10.10.100.253  255.255.255.0 

 ip helper-address10.10.1.1        

 standby 1 priority150 preempt 

 standby 1 ip10.10.100.254 

standby 1 track gi1/0/1

STP配置:

spanning-tree mode pvst

spanning-tree vlan 1 root primary

interface gi1/0/1

switch mode trunk

 

FW1配置:

Hostname FW1

Interface eth 0/0

Nameif ouside

Ip address 202.100.1.10 255.255.255.0 standby 102.100.1.20

 

Interface eth 0/1

Nameif inside

Ip address 10.1.1.10 255.255.255.0 standby 10.1.1.20

Interface eth0/2

No shut

 

Failover lan unit Primary

Failover lan interface FO eth 0/2

Failover key cisco

Failover interface ip FO 192.168.1.10 255.255.255.0 standby192.168.1.20

Fw2配置:

Interface eth0/2

No shut

Failover lan unit secondary

Failover lan interface FO eth0/2

Failover key cisco

Failover interface ip FO 192.168.1.10 255.255.255.0 standby192.168.1.20

Failover

Fw1配置stateful链路:

Interface eth0/3

No shut

Failover link stateful eth 0/3

Failover interface ip stateful 192.168.2.10 255.255.255.0standby 192.168.2.20

FW2上无需配置,因为FO链路可以把配置同步到FW2secondary上的

注意的是,ASAFWfailovertrigger的条件默认是,当设备坏掉,链路断掉时。具体参看:http://www.cisco.com/c/en/us/td/docs/security/asa/asa82/configuration/guide/config/ha_active_standby.html#wp1097144(查询FailoverTriggers内容)

 

 

参看:http://gponsolution.com/hsrp-tuning-example.html

 

 


本文转自 zhangfang526 51CTO博客,原文链接:http://blog.51cto.com/zhangfang526/1772382


相关文章
|
2月前
|
Ubuntu 网络安全 虚拟化
VMware虚拟机ping不通原因排查及分析
下面以 VMware 虚拟机为例进行介绍。
890 3
|
2月前
|
存储 SQL 数据库
虚拟化数据恢复—Vmware虚拟机误还原快照的数据恢复案例
虚拟化数据恢复环境: 一台虚拟机从物理机迁移到ESXI虚拟化平台,迁移完成后做了一个快照。虚拟机上运行了一个SQL Server数据库,记录了数年的数据。 ESXI虚拟化平台上有数十台虚拟机,EXSI虚拟化平台连接了一台EVA存储,所有的虚拟机都存放在EVA存储上。 虚拟化故障: 工组人员误操作将数年前迁移完成后做的快照还原了,也就意味着虚拟机状态还原到数年前,近几年数据都被删除了。 还原快照相当于删除数据,意味着部分存储空间会被释放。为了不让这部分释放的空间被重用,需要将连接到这台存储的所有虚拟机都关掉,需要将不能长时间宕机的虚拟机迁移到别的EXSI虚拟化平台上。
113 50
|
3月前
|
安全 虚拟化 数据中心
Xshell 连接 VMware虚拟机操作 截图和使用
Xshell 连接 VMware虚拟机操作 截图和使用
81 4
|
7月前
|
Unix Linux 虚拟化
虚拟机VMware知识积累
虚拟机VMware知识积累
|
3月前
|
Linux 虚拟化
vmware虚拟机安装2024(超详细)
vmware虚拟机安装2024(超详细)
413 6
|
3月前
|
虚拟化 网络虚拟化 网络架构
虚拟机 VMware Workstation 16 PRO 的网络配置
虚拟机 VMware Workstation 16 PRO 的网络配置
96 2
|
4月前
|
存储 SQL 数据挖掘
虚拟化数据恢复—VMware虚拟机vmdk文件被误删除的数据恢复案例
虚拟化数据恢复环境: 某品牌服务器(部署VMware EXSI虚拟机)+同品牌存储(存放虚拟机文件)。 虚拟化故障: 意外断电导致服务器上某台虚拟机无法正常启动。查看虚拟机配置文件发现这台故障虚拟机除了磁盘文件以外其他配置文件全部丢失,xxx-flat.vmdk磁盘文件和xxx-000001-delta.vmdk快照文件还在。管理员联系VMware工程师寻求帮助。VMware工程师尝试新建一个虚拟机来解决故障,但发现ESXi存储空间不足。于是将故障虚拟机下的xxx-flat.vmdk磁盘文件删除,然后重建一个虚拟机并且分配固定大小的虚拟磁盘。
|
5月前
|
测试技术 Linux 虚拟化
iOS自动化测试方案(五):保姆级VMware虚拟机安装MacOS
详细的VMware虚拟机安装macOS Big Sur的保姆级教程,包括下载VMware和macOS镜像、图解安装步骤和遇到问题时的解决方案,旨在帮助读者顺利搭建macOS虚拟机环境。
199 3
iOS自动化测试方案(五):保姆级VMware虚拟机安装MacOS