netapp fas2220更换硬盘的记录

本文涉及的产品
Redis 开源版,标准版 2GB
推荐场景:
搭建游戏排行榜
云数据库 Tair(兼容Redis),内存型 2GB
简介: netapp fas2220更换硬盘的记录

1、买来新的硬盘,出现broken的问题

如下:

fas2220> vol status -r
Aggregate aggr0 (online, raid_dp, reconstruct) (block checksums)
  Plex /aggr0/plex0 (online, normal, active, pool0)
    RAID group /aggr0/plex0/rg0 (reconstruction 5% completed, block checksums)
      RAID Disk    Device      HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Phys (MB/blks)
      ---------    ------      ------------- ---- ---- ---- ----- --------------    --------------
      dparity     0a.00.1     0a    0   1   SA:A   0  BSAS  7200 847555/1735794176 847884/1736466816 (reconstruction 5% completed)
      parity      0a.00.0     0a    0   0   SA:A   0  BSAS  7200 847555/1735794176 847884/1736466816 
      data        0a.00.10    0a    0   10  SA:A   0  BSAS  7200 847555/1735794176 847884/1736466816 
      data        0a.00.5     0a    0   5   SA:A   0  BSAS  7200 847555/1735794176 847884/1736466816 
      data        0a.00.9     0a    0   9   SA:A   0  BSAS  7200 847555/1735794176 847884/1736466816 
      data        0a.00.4     0a    0   4   SA:A   0  BSAS  7200 847555/1735794176 847884/1736466816 
      data        0a.00.2     0a    0   2   SA:A   0  BSAS  7200 847555/1735794176 847884/1736466816 
      data        0a.00.6     0a    0   6   SA:A   0  BSAS  7200 847555/1735794176 847884/1736466816 
      data        0a.00.3     0a    0   3   SA:A   0  BSAS  7200 847555/1735794176 847884/1736466816 
      data        0a.00.7     0a    0   7   SA:A   0  BSAS  7200 847555/1735794176 847884/1736466816 
      data        0a.00.11    0a    0   11  SA:A   0  BSAS  7200 847555/1735794176 847884/1736466816 
Pool1 spare disks (empty)
Pool0 spare disks (empty)
Broken disks
RAID Disk    Device      HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Phys (MB/blks)
---------    ------      ------------- ---- ---- ---- ----- --------------    --------------
bad label    0a.00.8     0a    0   8   SA:A   0  BSAS  7200 847555/1735794176 847884/1736466816

2、说明是bad label,需要进行下面操作

fas2220> priv set advanced
Warning: These advanced commands are potentially dangerous; use
         them only when directed to do so by NetApp
         personnel.
fas2220*> disk unfail -s 0a.00.8  这里-s 后面是上面的bad label的id
disk unfail: unfailing disk 0a.00.8...
fas2220*> Mon Dec  5 12:08:44 CST [fas2220:raid.disk.unfail.done:info]: Disk 0a.00.8 Shelf 0 Bay 8 [WDC      WD1003FBYZ-010SM 4321] S/N [     WD-WCAW31VC4KZP] unfailed, and is now a spare  
fas2220*> vol status -r         
Aggregate aggr0 (online, raid_dp, reconstruct) (block checksums)
  Plex /aggr0/plex0 (online, normal, active, pool0)
    RAID group /aggr0/plex0/rg0 (reconstruction 6% completed, block checksums)
      RAID Disk    Device      HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Phys (MB/blks)
      ---------    ------      ------------- ---- ---- ---- ----- --------------    --------------
      dparity     0a.00.1     0a    0   1   SA:A   0  BSAS  7200 847555/1735794176 847884/1736466816 (reconstruction 6% completed)
      parity      0a.00.0     0a    0   0   SA:A   0  BSAS  7200 847555/1735794176 847884/1736466816 
      data        0a.00.10    0a    0   10  SA:A   0  BSAS  7200 847555/1735794176 847884/1736466816 
      data        0a.00.5     0a    0   5   SA:A   0  BSAS  7200 847555/1735794176 847884/1736466816 
      data        0a.00.9     0a    0   9   SA:A   0  BSAS  7200 847555/1735794176 847884/1736466816 
      data        0a.00.4     0a    0   4   SA:A   0  BSAS  7200 847555/1735794176 847884/1736466816 
      data        0a.00.2     0a    0   2   SA:A   0  BSAS  7200 847555/1735794176 847884/1736466816 
      data        0a.00.6     0a    0   6   SA:A   0  BSAS  7200 847555/1735794176 847884/1736466816 
      data        0a.00.3     0a    0   3   SA:A   0  BSAS  7200 847555/1735794176 847884/1736466816 
      data        0a.00.7     0a    0   7   SA:A   0  BSAS  7200 847555/1735794176 847884/1736466816 
      data        0a.00.11    0a    0   11  SA:A   0  BSAS  7200 847555/1735794176 847884/1736466816 
Pool1 spare disks (empty)
Pool0 spare disks
RAID Disk    Device      HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Phys (MB/blks)
---------    ------      ------------- ---- ---- ---- ----- --------------    --------------
Spare disks for block checksum
spare       0a.00.8     0a    0   8   SA:A   0  BSAS  7200 847555/1735794176 847884/1736466816 (not zeroed)

3、进行清0操作

fas2220> 
fas2220> disk zero spares
fas2220> vol status -r   
Aggregate aggr0 (online, raid_dp, reconstruct) (block checksums)
  Plex /aggr0/plex0 (online, normal, active, pool0)
    RAID group /aggr0/plex0/rg0 (reconstruction 11% completed, block checksums)
      RAID Disk    Device      HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Phys (MB/blks)
      ---------    ------      ------------- ---- ---- ---- ----- --------------    --------------
      dparity     0a.00.1     0a    0   1   SA:A   0  BSAS  7200 847555/1735794176 847884/1736466816 (reconstruction 11% completed)
      parity      0a.00.0     0a    0   0   SA:A   0  BSAS  7200 847555/1735794176 847884/1736466816 
      data        0a.00.10    0a    0   10  SA:A   0  BSAS  7200 847555/1735794176 847884/1736466816 
      data        0a.00.5     0a    0   5   SA:A   0  BSAS  7200 847555/1735794176 847884/1736466816 
      data        0a.00.9     0a    0   9   SA:A   0  BSAS  7200 847555/1735794176 847884/1736466816 
      data        0a.00.4     0a    0   4   SA:A   0  BSAS  7200 847555/1735794176 847884/1736466816 
      data        0a.00.2     0a    0   2   SA:A   0  BSAS  7200 847555/1735794176 847884/1736466816 
      data        0a.00.6     0a    0   6   SA:A   0  BSAS  7200 847555/1735794176 847884/1736466816 
      data        0a.00.3     0a    0   3   SA:A   0  BSAS  7200 847555/1735794176 847884/1736466816 
      data        0a.00.7     0a    0   7   SA:A   0  BSAS  7200 847555/1735794176 847884/1736466816 
      data        0a.00.11    0a    0   11  SA:A   0  BSAS  7200 847555/1735794176 847884/1736466816 
Pool1 spare disks (empty)
Pool0 spare disks
RAID Disk    Device      HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Phys (MB/blks)
---------    ------      ------------- ---- ---- ---- ----- --------------    --------------
Spare disks for block checksum
spare       0a.00.8     0a    0   8   SA:A   0  BSAS  7200 847555/1735794176 847884/1736466816 (zeroing, 0% done)
fas2220>


相关实践学习
基于Redis实现在线游戏积分排行榜
本场景将介绍如何基于Redis数据库实现在线游戏中的游戏玩家积分排行榜功能。
云数据库 Redis 版使用教程
云数据库Redis版是兼容Redis协议标准的、提供持久化的内存数据库服务,基于高可靠双机热备架构及可无缝扩展的集群架构,满足高读写性能场景及容量需弹性变配的业务需求。 产品详情:https://www.aliyun.com/product/kvstore     ------------------------------------------------------------------------- 阿里云数据库体验:数据库上云实战 开发者云会免费提供一台带自建MySQL的源数据库 ECS 实例和一台目标数据库 RDS实例。跟着指引,您可以一步步实现将ECS自建数据库迁移到目标数据库RDS。 点击下方链接,领取免费ECS&RDS资源,30分钟完成数据库上云实战!https://developer.aliyun.com/adc/scenario/51eefbd1894e42f6bb9acacadd3f9121?spm=a2c6h.13788135.J_3257954370.9.4ba85f24utseFl
相关文章
|
6月前
|
存储 运维 数据挖掘
服务器数据恢复-DELL EqualLogic PS存储raid5数据恢复案例
服务器数据恢复环境: 一台DELL EqualLogic PS系列存储,存储中有一组由16块SAS硬盘组成的RAID5。上层是VMFS文件系统,存放虚拟机文件。存储上层分了4个卷。 服务器故障&检测: 存储上有2个硬盘指示灯显示黄色,磁盘出现故障导致存储不可用,存储设备已经过保。 硬件工程师对故障存储中的16块硬盘做了硬件故障检测,发现其中有2块磁盘存在坏道,SMART的错误冗余级别已经超过阈值。
服务器数据恢复-DELL EqualLogic PS存储raid5数据恢复案例
|
存储 文件存储
收藏帖!FreeNAS系统硬盘损坏更换教程,重组系统恢复数据
收藏帖!FreeNAS系统硬盘损坏更换教程,重组系统恢复数据
收藏帖!FreeNAS系统硬盘损坏更换教程,重组系统恢复数据
|
1月前
|
存储
服务器数据恢复—EMC存储RAID5阵列崩溃的数据恢复案例
服务器数据恢复环境: 一台EMC某型号存储设备,该存储中有一组由12块(包括2块热备盘)STAT硬盘组建的raid5阵列。 服务器故障: 该存储在运行过程中突然崩溃,raid瘫痪。数据恢复工程师到达现场对故障存储设备进行初检,发现raid中有两块硬盘掉线但只有一块热备盘成功激活,所以导致阵列瘫痪,上层lun无法使用。
|
8天前
|
存储 数据挖掘
服务器数据恢复—EqualLogic存储raid5阵列多块硬盘掉线的数据恢复案例
服务器存储数据恢复环境: 一台EqualLogic存储中有一组由16块SAS硬盘组建的RAID5阵列。上层划分了4个卷,采用VMFS文件系统,存放虚拟机文件。 服务器存储故障: 存储RAID5阵列中磁盘出现故障,有2块硬盘对应的指示灯亮黄灯,存储不可用,且存储设备已经过保。
|
1月前
|
固态存储 内存技术
升级电脑内存和硬盘
升级电脑内存和硬盘
43 6
|
6月前
|
存储 运维
服务器数据恢复—EqualLogic存储硬盘出现故障的数据恢复案例
服务器数据恢复环境: 一台某品牌EqualLogic PS 6011型号存储,底层有一组由16块SAS硬盘组建的RAID5阵列,上层存储空间划分了4个卷,格式化为VMFS文件系统,存放虚拟机文件。 服务器故障: 存储设备上两块硬盘指示灯显示黄色,磁盘出现故障导致存储不可用,存储已经过保,用户方联系北亚企安数据恢复中心要求恢复数据。
服务器数据恢复—EqualLogic存储硬盘出现故障的数据恢复案例
|
4月前
|
数据库
服务器数据恢复—同品牌不同系列服务器raid5阵列数据恢复案例
服务器数据恢复环境: 一台某品牌LH6000系列服务器,通过NetRaid阵列卡将4块硬盘组建为一组RAID5磁盘阵列。操作系统都为Window server,数据库是SQLServer。 服务器故障: LH6000系列服务器故障如下: 一块硬盘指示灯亮红灯,服务器还在正常运行,但没过多久,服务器就无法正常运行,这时另一块硬盘的指示灯变成红色。
|
6月前
|
数据挖掘 虚拟化 芯片
服务器数据恢复—某品牌P2000服务器raid5阵列数据恢复案例
服务器数据恢复环境: 某品牌P2000服务器,有一组由数块硬盘组建的raid5磁盘阵列(有热备盘),部署了VMWARE ESX虚拟化平台,VMFS文件系统。 服务器故障: 服务器在正常运行中,raid5阵列有两块硬盘亮黄色故障灯。经用户方工作人员初步检测,亮黄色故障灯的硬盘出现物理故障,故障表现为:序列号无法读取,通过SAS扩展卡无法识别硬盘。
服务器数据恢复—某品牌P2000服务器raid5阵列数据恢复案例
|
6月前
|
存储 算法 数据库
【服务器数据恢复】raid5多块硬盘离线导致昆腾存储崩溃的数据恢复案例
10个磁盘柜,每个磁盘柜配24块硬盘。9个磁盘柜用于存储数据,1个磁盘柜用于存储元数据。 元数据存储中24块硬盘,组建了9组RAID1阵列+1组RAID10阵列,4个全局热备硬盘。 数据存储中,组建了36组6硬RAID5,36组RAID5阵列划分为2个存储系统。其中1个存储系统中的一组RAID5中有2块硬盘先后出现故障离线,RAID5阵列不可用,存储系统崩溃。
【服务器数据恢复】raid5多块硬盘离线导致昆腾存储崩溃的数据恢复案例
|
11月前
|
存储 数据挖掘
服务器数据恢复—EMC存储raid5阵列瘫痪的数据恢复案例
服务器存储数据恢复环境: EMC某型号存储,8块组建一组raid5磁盘阵列。上层操作系统采用zfs文件系统。 服务器存储故障&分析: raid5阵列中有2块硬盘未知原因离线,raid5阵列崩溃,上层应用无法正常使用。
服务器数据恢复—EMC存储raid5阵列瘫痪的数据恢复案例