The parent virtual disk has been modified since the child was created

简介:

Problem:

wKioL1dXgvijpSoAAAA0FTIe0r8200.png


具体的消息是:

Failed to start the virtual machine.

Module DiskEarly power on failed.

Cannot open the disk '/vmfs/volumes/54627907-c2477c60-ec2b-0024e8573a7f/WebServer_Version2/WebServer_Version 2-000008.vmdk' or one of the snapshot disks it depends on.

The parent virtual disk hasbeen modified since the child was created. The content ID of the parent virtual disk doesnot match the corresponding parent content ID in the child




 


解决方法和思路:

--------------------------------------

1. 先开启任意一个机器上的SSH服务

2. 然后用ssh 登录到这个ESXI计算机上

3. 运行下面的命令

Cat WebServer_Version\ 2.vmdk

------------------------------------------------------------

# Disk DescriptorFile

version=1

encoding="UTF-8"

CID=60025a0a

parentCID=ffffffff

isNativeSnapshot="no"

createType="vmfs"

# Extent description

RW 167772160 VMFS "WebServer_Version 2-flat.vmdk"

# The Disk Data Base

#DDB

ddb.adapterType = "lsilogic"

ddb.deletable = "true"

ddb.geometry.cylinders = "10443"

ddb.geometry.heads = "255"

ddb.geometry.sectors = "63"

ddb.longContentID ="4335f3cc11a7c8500cdb139a60025a0a"

ddb.uuid = "60 00 C2 99 f5 15 36 81-06 e3 f8 b6 66 dc30 de"

ddb.virtualHWVersion = "8"

 

/vmfs/volumes/54627907-c2477c60-ec2b-0024e8573a7f/WebServer_Version2 # cat WebServer_Version\ 2-000008.vmdk

# Disk DescriptorFile

version=1

encoding="UTF-8"

CID=7e05ba5d

parentCID=75d5382b


createType="vmfsSparse"

parentFileNameHint="WebServer_Version 2.vmdk"

# Extent description

RW 167772160 VMFSSPARSE "WebServer_Version2-000008-delta.vmdk"

# The Disk Data Base

#DDB

ddb.longContentID = "901af6c76efda040f8d76a817e05ba5d"


4. 在检查的vmdk中,我们可以看到parentCID是和上面的CID不一样的。

5. 然后把备份这个文件夹通过下载的方法

6. 编辑WebServer_Version\ 2-000008.vmdk中的ParentCID为60025a0a


P.S.

在ESXI中所有的VM都存放在/vmfs/volumes下面,后面的一串ID是和我们建立存储的friendly的一个硬连接


本文转自 zhangfang526 51CTO博客,原文链接:http://blog.51cto.com/zhangfang526/1787202


相关文章
Unknown custom element: <add-employee> - did you register the component correctly? For red cursive c
原因: 1.组件名没写对(导入和注册不对应) 2.components少写了个s 3.组件命名最好是驼峰命名 4.导入时语法错误 5.代码中有两个components,后一个的值把前一个覆盖了 6.组件直接循环套用了
104 0
|
前端开发 5G
Search space set group switching(一)
根据R17 38.300的描述,UE可以通过PDCCH monitoring adaptation机制实现power saving的目的,这其中就包括PDCCH monitoring skipping和search space set group (SSSG) switching两种机制。PDCCH monitoring skipping是R17才提出的机制,就是UE 可以在PDCCH skipping的时间内不监视 PDCCH的功能;search space set group (SSSG) switching R16提出,R17进行了部分增强。
MGA (Managed Global Area) Reference Note (Doc ID 2638904.1)
MGA (Managed Global Area) Reference Note (Doc ID 2638904.1)
341 0
SAP WM Storage Type Capacity Check Method 5 (Usage check based on SUT)
SAP WM Storage Type Capacity Check Method 5 (Usage check based on SUT)
SAP WM Storage Type Capacity Check Method 5 (Usage check based on SUT)
SAP WM中阶Storage Type的Capacity Check – Check based on maximum quantity per bin in storage type.
SAP WM中阶Storage Type的Capacity Check – Check based on maximum quantity per bin in storage type.
SAP WM中阶Storage Type的Capacity Check – Check based on maximum quantity per bin in storage type.
SAP WM中阶Storage Type的Capacity Check – Usage check based on material
SAP WM中阶Storage Type的Capacity Check – Usage check based on material
SAP WM中阶Storage Type的Capacity Check – Usage check based on material
SAP WM 为Storage Type 004激活SUM报错 - Storage types without pick-point stor.type require partial pallet
SAP WM 为Storage Type 004激活SUM报错 - Storage types without pick-point stor.type require partial pallet
SAP WM 为Storage Type 004激活SUM报错 - Storage types without pick-point stor.type require partial pallet