Oracle 小型机T7-1更换rpool中的硬盘

本文涉及的产品
函数计算FC,每月15万CU 3个月
简介:
  1. 确定故障原因

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
root@ test  # fmadm faulty
--------------- ------------------------------------  -------------- ---------
TIME            EVENT-ID                              MSG-ID         SEVERITY
--------------- ------------------------------------  -------------- ---------
Oct 30 22:11:10 8ad90d8d-3e4f-432d-a233-84f8627dcf10  DISK-8000-0X   Major    
 
Problem Status    :  open
Diag Engine       : eft / 1.16
System
     Manufacturer  : Oracle Corporation
     Name          : SPARC T7-1
     Part_Number   : 34429612+1+1
     Serial_Number : AK00373594
     Host_ID       : 86bb603a
 
----------------------------------------
Suspect 1 of 1 :
    Problem class : fault.io.disk.predictive-failure
    Certainty   : 100%
    Affects     : dev: /// :devid=id1,sd@n5000cca02f1d2524 //scsi_vhci/disk @g5000cca02f1d2524
    Status      : faulted but still providing degraded service
 
    FRU
      Status           : faulty
      Location         :  "/SYS/DBP/HDD0"
      Manufacturer     : HGST
      Name             : H101860SFSUN600G
      Part_Number      : HGST-H101860SFSUN600G
      Revision         : A990
      Serial_Number    : 001619FJ0WNC--------03GJ0WNC
      Chassis
         Manufacturer  : Oracle Corporation
         Name          : SPARC T7-1
         Part_Number   : 34429612+1+1
         Serial_Number : AK00373594
 
Description : SMART health-monitoring firmware reported that a disk failure is
               imminent.
 
Response    : A hot-spare disk may have been activated.
 
Impact      : It is likely that the continued operation of this disk will
               result  in  data loss.
 
Action      : Use  'fmadm faulty'  to provide a  more  detailed view of this event.
               Please refer to the associated reference document at
               http: //support .oracle.com /msg/DISK-8000-0X  for  the latest service
               procedures and policies regarding this diagnosis.
root@ test  # more /var/adm/messages 
Nov  8 16:23:13 zbwl03 scsi: [ID 243001 kern.warning] WARNING:  /scsi_vhci/disk @g5000cca02f1d2524 (sd5):
Nov  8 16:23:13 zbwl03  Error  for  Command:  read (10)                Error Level: Informational
Nov  8 16:23:13 zbwl03 scsi: [ID 243001 kern.info]      Requested Block: 394604487                 Error Block: 394604487
Nov  8 16:23:13 zbwl03 scsi: [ID 243001 kern.info]      Vendor: HGST                               Serial Number: 1619FJ0WNC  
Nov  8 16:23:13 zbwl03 scsi: [ID 243001 kern.info]      Sense Key: Soft_Error
Nov  8 16:23:13 zbwl03 scsi: [ID 243001 kern.info]      ASC: 0x5d (<vendor unique code 0x5d>), ASCQ: 0x90, FRU: 0x90
Nov  8 17:06:27 zbwl03 scsi: [ID 243001 kern.warning] WARNING:  /scsi_vhci/disk @g5000cca02f1d2524 (sd5):
Nov  8 17:06:27 zbwl03  Error  for  Command:  read (10)                Error Level: Informational
Nov  8 17:06:27 zbwl03 scsi: [ID 243001 kern.info]      Requested Block: 118860647                 Error Block: 118860647
Nov  8 17:06:27 zbwl03 scsi: [ID 243001 kern.info]      Vendor: HGST                               Serial Number: 1619FJ0WNC  
Nov  8 17:06:27 zbwl03 scsi: [ID 243001 kern.info]      Sense Key: Soft_Error
Nov  8 17:06:27 zbwl03 scsi: [ID 243001 kern.info]      ASC: 0x5d (<vendor unique code 0x5d>), ASCQ: 0x90, FRU: 0x90
Nov  8 17:11:11 zbwl03 scsi: [ID 243001 kern.warning] WARNING:  /scsi_vhci/disk @g5000cca02f1d2524 (sd5):
Nov  8 17:11:11 zbwl03  Error  for  Command:  read (10)                Error Level: Informational
Nov  8 17:11:11 zbwl03 scsi: [ID 243001 kern.info]      Requested Block: 86417744                  Error Block: 86417744
Nov  8 17:11:11 zbwl03 scsi: [ID 243001 kern.info]      Vendor: HGST                               Serial Number: 1619FJ0WNC  
Nov  8 17:11:11 zbwl03 scsi: [ID 243001 kern.info]      Sense Key: Soft_Error
Nov  8 17:11:11 zbwl03 scsi: [ID 243001 kern.info]      ASC: 0x5d (<vendor unique code 0x5d>), ASCQ: 0x90, FRU: 0x90
Nov  8 17:36:14 zbwl03 scsi: [ID 243001 kern.warning] WARNING:  /scsi_vhci/disk @g5000cca02f1d2524 (sd5):
Nov  8 17:36:14 zbwl03  Error  for  Command:  read (10)                Error Level: Informational
Nov  8 17:36:14 zbwl03 scsi: [ID 243001 kern.info]      Requested Block: 118915795                 Error Block: 118915795
Nov  8 17:36:14 zbwl03 scsi: [ID 243001 kern.info]      Vendor: HGST                               Serial Number: 1619FJ0WNC  
Nov  8 17:36:14 zbwl03 scsi: [ID 243001 kern.info]      Sense Key: Soft_Error
Nov  8 17:36:14 zbwl03 scsi: [ID 243001 kern.info]      ASC: 0x5d (<vendor unique code 0x5d>), ASCQ: 0x90, FRU: 0x90
Nov  8 17:54:11 zbwl03 scsi: [ID 243001 kern.warning] WARNING:  /scsi_vhci/disk @g5000cca02f1d2524 (sd5):
Nov  8 17:54:11 zbwl03  Error  for  Command:  read (10)                Error Level: Informational
Nov  8 17:54:11 zbwl03 scsi: [ID 243001 kern.info]      Requested Block: 86417744                  Error Block: 86417744
Nov  8 17:54:11 zbwl03 scsi: [ID 243001 kern.info]      Vendor: HGST                               Serial Number: 1619FJ0WNC  
Nov  8 17:54:11 zbwl03 scsi: [ID 243001 kern.info]      Sense Key: Soft_Error
Nov  8 17:54:11 zbwl03 scsi: [ID 243001 kern.info]      ASC: 0x5d (<vendor unique code 0x5d>), ASCQ: 0x90, FRU: 0x90
Nov  8 19:11:49 zbwl03 scsi: [ID 243001 kern.warning] WARNING:  /scsi_vhci/disk @g5000cca02f1d2524 (sd5):
Nov  8 19:11:49 zbwl03  Error  for  Command:  read (10)                Error Level: Informational
Nov  8 19:11:49 zbwl03 scsi: [ID 243001 kern.info]      Requested Block: 211206686                 Error Block: 211206686
Nov  8 19:11:49 zbwl03 scsi: [ID 243001 kern.info]      Vendor: HGST                               Serial Number: 1619FJ0WNC  
Nov  8 19:11:49 zbwl03 scsi: [ID 243001 kern.info]      Sense Key: Soft_Error
Nov  8 19:11:49 zbwl03 scsi: [ID 243001 kern.info]      ASC: 0x5d (<vendor unique code 0x5d>), ASCQ: 0x90, FRU: 0x90
Nov  8 20:16:45 zbwl03 scsi: [ID 243001 kern.warning] WARNING:  /scsi_vhci/disk @g5000cca02f1d2524 (sd5):
Nov  8 20:16:45 zbwl03  Error  for  Command:  read (10)                Error Level: Informational
Nov  8 20:16:45 zbwl03 scsi: [ID 243001 kern.info]      Requested Block: 213848167                 Error Block: 213848167
Nov  8 20:16:45 zbwl03 scsi: [ID 243001 kern.info]      Vendor: HGST                               Serial Number: 1619FJ0WNC  
Nov  8 20:16:45 zbwl03 scsi: [ID 243001 kern.info]      Sense Key: Soft_Error
Nov  8 20:16:45 zbwl03 scsi: [ID 243001 kern.info]      ASC: 0x5d (<vendor unique code 0x5d>), ASCQ: 0x90, FRU: 0x90
Nov  8 20:21:55 zbwl03 scsi: [ID 243001 kern.warning] WARNING:  /scsi_vhci/disk @g5000cca02f1d2524 (sd5):
Nov  8 20:21:55 zbwl03  Error  for  Command:  read (10)                Error Level: Informational
Nov  8 20:21:55 zbwl03 scsi: [ID 243001 kern.info]      Requested Block: 209782185                 Error Block: 209782185
Nov  8 20:21:55 zbwl03 scsi: [ID 243001 kern.info]      Vendor: HGST                               Serial Number: 1619FJ0WNC  
Nov  8 20:21:55 zbwl03 scsi: [ID 243001 kern.info]      Sense Key: Soft_Error
Nov  8 20:21:55 zbwl03 scsi: [ID 243001 kern.info]      ASC: 0x5d (<vendor unique code 0x5d>), ASCQ: 0x90, FRU: 0x90
Nov  8 20:27:08 zbwl03 scsi: [ID 243001 kern.warning] WARNING:  /scsi_vhci/disk @g5000cca02f1d2524 (sd5):
Nov  8 20:27:08 zbwl03  Error  for  Command:  read (10)                Error Level: Informational
Nov  8 20:27:08 zbwl03 scsi: [ID 243001 kern.info]      Requested Block: 213848182                 Error Block: 213848182
Nov  8 20:27:08 zbwl03 scsi: [ID 243001 kern.info]      Vendor: HGST                               Serial Number: 1619FJ0WNC  
Nov  8 20:27:08 zbwl03 scsi: [ID 243001 kern.info]      Sense Key: Soft_Error
Nov  8 20:27:08 zbwl03 scsi: [ID 243001 kern.info]      ASC: 0x5d (<vendor unique code 0x5d>), ASCQ: 0x90, FRU: 0x90
Nov  8 20:37:29 zbwl03 scsi: [ID 243001 kern.warning] WARNING:  /scsi_vhci/disk @g5000cca02f1d2524 (sd5):
Nov  8 20:37:29 zbwl03  Error  for  Command:  read (10)                Error Level: Informational
Nov  8 20:37:29 zbwl03 scsi: [ID 243001 kern.info]      Requested Block: 211019254                 Error Block: 211019254
Nov  8 20:37:29 zbwl03 scsi: [ID 243001 kern.info]      Vendor: HGST                               Serial Number: 1619FJ0WNC  
Nov  8 20:37:29 zbwl03 scsi: [ID 243001 kern.info]      Sense Key: Soft_Error
Nov  8 20:37:29 zbwl03 scsi: [ID 243001 kern.info]      ASC: 0x5d (<vendor unique code 0x5d>), ASCQ: 0x90, FRU: 0x90
Nov  8 20:42:42 zbwl03 scsi: [ID 243001 kern.warning] WARNING:  /scsi_vhci/disk @g5000cca02f1d2524 (sd5):
Nov  8 20:42:42 zbwl03  Error  for  Command:  read (10)                Error Level: Informational
Nov  8 20:42:42 zbwl03 scsi: [ID 243001 kern.info]      Requested Block: 211955388                 Error Block: 211955388
Nov  8 20:42:42 zbwl03 scsi: [ID 243001 kern.info]      Vendor: HGST                               Serial Number: 1619FJ0WNC  
Nov  8 20:42:42 zbwl03 scsi: [ID 243001 kern.info]      Sense Key: Soft_Error
Nov  8 20:42:42 zbwl03 scsi: [ID 243001 kern.info]      ASC: 0x5d (<vendor unique code 0x5d>), ASCQ: 0x90, FRU: 0x90
Nov  8 20:58:15 zbwl03 scsi: [ID 243001 kern.warning] WARNING:  /scsi_vhci/disk @g5000cca02f1d2524 (sd5):
Nov  8 20:58:15 zbwl03  Error  for  Command:  read (10)                Error Level: Informational
Nov  8 20:58:15 zbwl03 scsi: [ID 243001 kern.info]      Requested Block: 213894761                 Error Block: 213894761
Nov  8 20:58:15 zbwl03 scsi: [ID 243001 kern.info]      Vendor: HGST                               Serial Number: 1619FJ0WNC  
Nov  8 20:58:15 zbwl03 scsi: [ID 243001 kern.info]      Sense Key: Soft_Error
Nov  8 20:58:15 zbwl03 scsi: [ID 243001 kern.info]      ASC: 0x5d (<vendor unique code 0x5d>), ASCQ: 0x90, FRU: 0x90
Nov  8 21:08:38 zbwl03 scsi: [ID 243001 kern.warning] WARNING:  /scsi_vhci/disk @g5000cca02f1d2524 (sd5):
                             Serial Number: 1619FJ0WNC 
root@ test  # zpool status rpool
   pool: rpool
  state: DEGRADED
status: One or  more  devices are unavailable  in  response to persistent errors.
         Sufficient replicas exist  for  the pool to  continue  functioning  in  a
         degraded state.
action: Determine  if  the device needs to be replaced, and  clear  the errors
         using  'zpool clear'  or  'fmadm repaired' , or replace the device
         with  'zpool replace' .
         Run  'zpool status -v'  to see device specific details.
   scan: resilvered 191G  in  18m17s with 0 errors on Wed Aug 31 20:15:31 2016
 
config:
 
         NAME                       STATE     READ WRITE CKSUM
         rpool                      DEGRADED     0     0     0
           mirror-0                 DEGRADED     0     0     0
             c0t5000CCA02F1D2524d0  DEGRADED     0     0     0
             c0t5000CCA02F1D7534d0  ONLINE       0     0     0
 
errors: No known data errors

   2.具体操作步骤

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
root@ test  # zpool offline rpool c0t5000CCA02F1D2524d0
root@ test  # zpool status rpool
   pool: rpool
  state: DEGRADED
status: One or  more  devices has been taken offline by the administrator.
         Sufficient replicas exist  for  the pool to  continue  functioning  in  a
         degraded state.
action: Online the device using  'zpool online'  or replace the device with
         'zpool replace' .
   scan: resilvered 191G  in  18m17s with 0 errors on Wed Aug 31 20:15:31 2016
 
config:
 
         NAME                       STATE     READ WRITE CKSUM
         rpool                      DEGRADED     0     0     0
           mirror-0                 DEGRADED     0     0     0
             c0t5000CCA02F1D2524d0  OFFLINE      0     0     0
             c0t5000CCA02F1D7534d0  ONLINE       0     0     0
 
errors: No known data errors
root@ test  # cfgadm -al
Ap_Id                          Type         Receptacle   Occupant     Condition
c4                             fc           connected    unconfigured unknown
c5                             fc-fabric    connected    configured   unknown
c5::2100000e1ecb1261           unknown      connected    unconfigured unknown
c5::2100000e1ecc7100           disk         connected    configured   unknown
c5::2100000e1ecc8320           disk         connected    configured   unknown
c6                             scsi-sas     connected    unconfigured unknown
c7                             scsi-sas     connected    configured   unknown
c7::w5000cca02f1d2524,0        disk-path    connected    configured   unknown
c8                             scsi-sas     connected    configured   unknown
c8::w5000cca02f1d7535,0        disk-path    connected    configured   unknown
c9                             fc           connected    unconfigured unknown
c11                            fc-fabric    connected    configured   unknown
c11::2100000e1ecb11f1          unknown      connected    unconfigured unknown
c11::2100000e1ecc8350          disk         connected    configured   unknown
c11::2100000e1ecc84c0          disk         connected    configured   unknown
usb0 /1                          unknown      empty        unconfigured ok
usb0 /2                          unknown      empty        unconfigured ok
usb0 /3                          usb-hub      connected    configured   ok
usb0 /3 .1                       usb-device   connected    configured   ok
usb0 /3 .2                       usb-communications connected    configured   ok
usb0 /3 .3                       unknown      empty        unconfigured ok
usb0 /3 .4                       unknown      empty        unconfigured ok
usb0 /4                          usb-hub      connected    configured   ok
usb0 /4 .1                       unknown      empty        unconfigured ok
usb0 /4 .2                       usb-storage  connected    configured   ok
usb0 /5                          unknown      empty        unconfigured ok
usb0 /6                          unknown      empty        unconfigured ok
usb0 /7                          usb-hub      connected    configured   ok
usb0 /7 .1                       unknown      empty        unconfigured ok
usb0 /7 .2                       unknown      empty        unconfigured ok
usb0 /7 .3                       unknown      empty        unconfigured ok
usb0 /7 .4                       unknown      empty        unconfigured ok
usb0 /8                          usb-hub      connected    configured   ok
usb0 /8 .1                       usb-device   connected    configured   ok
usb0 /8 .2                       unknown      empty        unconfigured ok

记住位置编号,unconfigure故障磁盘

1
2
c7::w5000cca02f1d2524,0
root@ test  # cfgadm -c unconfigure  c7::w5000cca02f1d2524,0

拨出故障硬盘,插入新的磁盘

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
root@ test  # cfgadm -al
Ap_Id                          Type         Receptacle   Occupant     Condition
c4                             fc           connected    unconfigured unknown
c5                             fc-fabric    connected    configured   unknown
c5::2100000e1ecb1261           unknown      connected    unconfigured unknown
c5::2100000e1ecc7100           disk         connected    configured   unknown
c5::2100000e1ecc8320           disk         connected    configured   unknown
c6                             scsi-sas     connected    unconfigured unknown
c7                             scsi-sas     connected    configured   unknown
c7::w5000cca02f1091b9,0        disk-path    connected    configured   unknown
c8                             scsi-sas     connected    configured   unknown
c8::w5000cca02f1d7535,0        disk-path    connected    configured   unknown
c9                             fc           connected    unconfigured unknown
c11                            fc-fabric    connected    configured   unknown
c11::2100000e1ecb11f1          unknown      connected    unconfigured unknown
c11::2100000e1ecc8350          disk         connected    configured   unknown
c11::2100000e1ecc84c0          disk         connected    configured   unknown
usb0 /1                          unknown      empty        unconfigured ok
usb0 /2                          unknown      empty        unconfigured ok
usb0 /3                          usb-hub      connected    configured   ok
usb0 /3 .1                       usb-device   connected    configured   ok
usb0 /3 .2                       usb-communications connected    configured   ok
usb0 /3 .3                       unknown      empty        unconfigured ok
usb0 /3 .4                       unknown      empty        unconfigured ok
usb0 /4                          usb-hub      connected    configured   ok
usb0 /4 .1                       unknown      empty        unconfigured ok
usb0 /4 .2                       usb-storage  connected    configured   ok
usb0 /5                          unknown      empty        unconfigured ok
usb0 /6                          unknown      empty        unconfigured ok
usb0 /7                          usb-hub      connected    configured   ok
usb0 /7 .1                       unknown      empty        unconfigured ok
usb0 /7 .2                       unknown      empty        unconfigured ok
usb0 /7 .3                       unknown      empty        unconfigured ok
usb0 /7 .4                       unknown      empty        unconfigured ok
usb0 /8                          usb-hub      connected    configured   ok
usb0 /8 .1                       usb-device   connected    configured   ok
usb0 /8 .2                       unknown      empty        unconfigured ok
root@ test  # cfgadm -c configure  c7::w5000cca02f1091b9,0
root@ test  # format
Searching  for  disks... done
 
 
AVAILABLE DISK SELECTIONS:
        0. c0t5000CCA02F1091B8d0 <HGST-H101860SFSUN600G-A990-558.91GB>  solaris
           /scsi_vhci/disk @g5000cca02f1091b8
           /dev/chassis/SYS/DBP/HDD0/disk
        1. c0t5000CCA02F1D7534d0 <HGST-H101860SFSUN600G-A990-558.91GB>
           /scsi_vhci/disk @g5000cca02f1d7534
           /dev/chassis/SYS/DBP/HDD1/disk
        2. c2t0d0 <MICRON-eUSB DISK-1112 cyl 246 alt 0 hd 255 sec 63>
           /pci @300 /pci @2 /usb @0 /hub @4 /storage @2 /disk @0,0
           /dev/chassis/SYS/MB/EUSB-DISK/disk
        3. c0t6000B08414B303033373335353600004d0 <Oracle-Oracle FS1-2-6203-800.83GB>
           /scsi_vhci/ssd @g6000b08414b303033373335353600004
        4. c0t6000B08414B303033373335353600005d0 <Oracle-Oracle FS1-2-6203-800.83GB>
           /scsi_vhci/ssd @g6000b08414b303033373335353600005
        5. c0t6000B08414B303033373335353600003d0 <Oracle-Oracle FS1-2-6203-2.00TB>
           /scsi_vhci/ssd @g6000b08414b303033373335353600003
        6. c0t6000B08414B303033373335353600000d0 <Oracle-Oracle FS1-2-6203-2.00TB>
           /scsi_vhci/ssd @g6000b08414b303033373335353600000
        7. c0t6000B08414B303033373335353600001d0 <Oracle-Oracle FS1-2-6203-2.00TB>
           /scsi_vhci/ssd @g6000b08414b303033373335353600001
        8. c0t6000B08414B303033373335353600002d0 <Oracle-Oracle FS1-2-6203-2.00TB>
           /scsi_vhci/ssd @g6000b08414b303033373335353600002
        9. c0t6000B08414B303033373335353600006d0 <Oracle-Oracle FS1-2-6203 cyl 575 alt 2 hd 128 sec 32>
           /scsi_vhci/ssd @g6000b08414b303033373335353600006
Specify disk (enter its number): ^C
root@ test  # zpool help replace
usage:
         replace [-f] <pool> <device> [new-device]
root@ test  # zpool replace rpool c0t5000CCA02F1D2524d0 c0t5000CCA02F1091B8d0
Make sure to wait  until  resilver is  done  before rebooting.
root@zbwl03  # zpool status rpool
   pool: rpool
  state: DEGRADED
status: One or  more  devices is currently being resilvered.  The pool will
         continue  to  function  in  a degraded state.
action: Wait  for  the resilver to complete.
         Run  'zpool status -v'  to see device specific details.
   scan: resilver  in  progress since Tue Nov 14 10:38:00 2017
     74.5G scanned out of 165G at 2.87G /s , 31s to go
     0 resilvered
config:
 
         NAME                         STATE     READ WRITE CKSUM
         rpool                        DEGRADED     0     0     0
           mirror-0                   DEGRADED     0     0     0
             replacing-0              DEGRADED     0     0     0
               c0t5000CCA02F1D2524d0  OFFLINE      0     0     0
               c0t5000CCA02F1091B8d0  DEGRADED     0     0     0  (resilvering)
             c0t5000CCA02F1D7534d0    ONLINE       0     0     0
 
errors: No known data errors
root@ test  # zpool status rpool
   pool: rpool
  state: DEGRADED
status: One or  more  devices is currently being resilvered.  The pool will
         continue  to  function  in  a degraded state.
action: Wait  for  the resilver to complete.
         Run  'zpool status -v'  to see device specific details.
   scan: resilver  in  progress since Tue Nov 14 10:38:00 2017
     165G scanned
     34.4G resilvered at 183M /s , 20.91%  done , 12m08s to go
config:
 
         NAME                         STATE     READ WRITE CKSUM
         rpool                        DEGRADED     0     0     0
           mirror-0                   DEGRADED     0     0     0
             replacing-0              DEGRADED    14     0     0
               c0t5000CCA02F1D2524d0  OFFLINE      0     0     0
               c0t5000CCA02F1091B8d0  DEGRADED     0     0     0  (resilvering)
             c0t5000CCA02F1D7534d0    ONLINE       0     0     0
 
errors: No known data errors
root@ test  # zpool status rpool
   pool: rpool
  state: DEGRADED
status: One or  more  devices is currently being resilvered.  The pool will
         continue  to  function  in  a degraded state.
action: Wait  for  the resilver to complete.
         Run  'zpool status -v'  to see device specific details.
   scan: resilver  in  progress since Tue Nov 14 10:38:00 2017
     165G scanned
     161G resilvered at 157M /s , 97.98%  done , 21s to go
config:
 
         NAME                         STATE     READ WRITE CKSUM
         rpool                        DEGRADED     0     0     0
           mirror-0                   DEGRADED     0     0     0
             replacing-0              DEGRADED    14     0     0
               c0t5000CCA02F1D2524d0  OFFLINE      0     0     0
               c0t5000CCA02F1091B8d0  DEGRADED     0     0     0  (resilvering)
             c0t5000CCA02F1D7534d0    ONLINE       0     0     0
 
errors: No known data errors
root@ test  # zpool status rpool
   pool: rpool
  state: DEGRADED
   scan: resilvered 165G  in  19m26s with 0 errors on Tue Nov 14 10:57:26 2017
 
config:
 
         NAME                         STATE     READ WRITE CKSUM
         rpool                        DEGRADED     0     0     0
           mirror-0                   DEGRADED     0     0     0
             replacing-0              DEGRADED    14     0     0
               c0t5000CCA02F1D2524d0  OFFLINE      0     0     0
               c0t5000CCA02F1091B8d0  ONLINE       0     0     0
             c0t5000CCA02F1D7534d0    ONLINE       0     0     0
 
errors: No known data errors
root@ test  # zpool status rpool
   pool: rpool
  state: ONLINE
   scan: resilvered 165G  in  19m26s with 0 errors on Tue Nov 14 10:57:26 2017
 
config:
 
         NAME                       STATE     READ WRITE CKSUM
         rpool                      ONLINE       0     0     0
           mirror-0                 ONLINE       0     0     0
             c0t5000CCA02F1091B8d0  ONLINE       0     0     0
             c0t5000CCA02F1D7534d0  ONLINE       0     0     0
 
errors: No known data errors
root@ test  #


























本文转自lq201151CTO博客,原文链接:http://blog.51cto.com/liuqun/1981726 ,如需转载请自行联系原作者


相关实践学习
【AI破次元壁合照】少年白马醉春风,函数计算一键部署AI绘画平台
本次实验基于阿里云函数计算产品能力开发AI绘画平台,可让您实现“破次元壁”与角色合照,为角色换背景效果,用AI绘图技术绘出属于自己的少年江湖。
从 0 入门函数计算
在函数计算的架构中,开发者只需要编写业务代码,并监控业务运行情况就可以了。这将开发者从繁重的运维工作中解放出来,将精力投入到更有意义的开发任务上。
相关文章
|
Oracle 关系型数据库 Linux
windows 11 hyper-v中oracle linux虚拟机中添加硬盘
在windows 11自带的hyper-v虚拟机中添加硬盘,并分区
403 6
|
Oracle 关系型数据库
oracle 11g rac asm磁盘组增加硬盘
要增加磁盘的磁盘组为:DATA 要增加的磁盘为: /dev/sde1 在第一个节点上:[root@rac1 ~]# fdisk /dev/sdeDevice contains neither a valid DOS partition table, nor Sun, SGI or OSF disklabelBuilding a new DOS disklabel.
1038 0
|
2月前
|
Oracle 关系型数据库 Linux
【赵渝强老师】Oracle数据库配置助手:DBCA
Oracle数据库配置助手(DBCA)是用于创建和配置Oracle数据库的工具,支持图形界面和静默执行模式。本文介绍了使用DBCA在Linux环境下创建数据库的完整步骤,包括选择数据库操作类型、配置存储与网络选项、设置管理密码等,并提供了界面截图与视频讲解,帮助用户快速掌握数据库创建流程。
346 93
|
1月前
|
Oracle 关系型数据库 Linux
【赵渝强老师】使用NetManager创建Oracle数据库的监听器
Oracle NetManager是数据库网络配置工具,用于创建监听器、配置服务命名与网络连接,支持多数据库共享监听,确保客户端与服务器通信顺畅。
176 0
|
4月前
|
存储 Oracle 关系型数据库
服务器数据恢复—光纤存储上oracle数据库数据恢复案例
一台光纤服务器存储上有16块FC硬盘,上层部署了Oracle数据库。服务器存储前面板2个硬盘指示灯显示异常,存储映射到linux操作系统上的卷挂载不上,业务中断。 通过storage manager查看存储状态,发现逻辑卷状态失败。再查看物理磁盘状态,发现其中一块盘报告“警告”,硬盘指示灯显示异常的2块盘报告“失败”。 将当前存储的完整日志状态备份下来,解析备份出来的存储日志并获得了关于逻辑卷结构的部分信息。
|
2月前
|
SQL Oracle 关系型数据库
Oracle数据库创建表空间和索引的SQL语法示例
以上SQL语法提供了一种标准方式去组织Oracle数据库内部结构,并且通过合理使用可以显著改善查询速度及整体性能。需要注意,在实际应用过程当中应该根据具体业务需求、系统资源状况以及预期目标去合理规划并调整参数设置以达到最佳效果。
278 8
|
4月前
|
SQL Oracle 关系型数据库
比较MySQL和Oracle数据库系统,特别是在进行分页查询的方法上的不同
两者的性能差异将取决于数据量大小、索引优化、查询设计以及具体版本的数据库服务器。考虑硬件资源、数据库设计和具体需求对于实现优化的分页查询至关重要。开发者和数据库管理员需要根据自身使用的具体数据库系统版本和环境,选择最合适的分页机制,并进行必要的性能调优来满足应用需求。
244 11
|
4月前
|
Oracle 关系型数据库 数据库
数据库数据恢复—服务器异常断电导致Oracle数据库报错的数据恢复案例
Oracle数据库故障: 某公司一台服务器上部署Oracle数据库。服务器意外断电导致数据库报错,报错内容为“system01.dbf需要更多的恢复来保持一致性”。该Oracle数据库没有备份,仅有一些断断续续的归档日志。 Oracle数据库恢复流程: 1、检测数据库故障情况; 2、尝试挂起并修复数据库; 3、解析数据库文件; 4、导出并验证恢复的数据库文件。

推荐镜像

更多