Bently 3500 PWA 163179-02F Temperature Monitor 3500/61

简介: Bently 3500 PWA 163179-02F 温度监测器 3500/61 提供六通道温度监测,支持RTD和热电偶输入。模块对输入信号进行处理,并与用户设定的报警点比较。3500/61相比3500/60额外提供每通道记录输出。该系列模块通过3500机架配置软件编程,支持RTD或热电偶温度测量。符合FCC、EMC、电气安全及RoHS等标准,设计满足IEC 62443网络安全要求,适用于船舶和海上单位分类规则。

Bently 3500 PWA 163179-02F Temperature Monitor 3500/61

Description

The 3500/60 & 61 modules provide six channels of temperature monitoring and accept both Resistance Temperature Detector (RTD) and Thermocouple (TC) temperature inputs. The modules condition these inputs and compare them against user-programmable alarm setpoints. The 3500/60 and 3500/61 provide identical functionality except that the 3500/61 provides recorder outputs for each of its six channels while the 3500/60 does not. The user programs the modules to perform either RTD or TC temperature measurements using the 3500 Rack Configuration Software. Different I/O modules are available in RTD/TC non-isolated or TC isolated versions. The user can configure the RTD/TC non-isolated version to accept either TC or RTD, or a mixture of TC and RTD inputs. The TC isolated version provides 250 Vdc of channel-to-channel isolation to protect against external interference. When used in a Triple Modular Redundant (TMR) configuration, temperature monitors must be installed adjacent to each other in groups of three. When used in this configuration, the system employs two types of voting to ensure accurate operation and to avoid single-point failures.

Compliance and Certifications (Approvals pending) FCC This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: l This device may not cause harmful interference. l This device must accept any interference received, including interference that may cause undesired operation. EMC European Community Directive: EMC Directive 2014/30/EU Standards: EN 61000-6-2; Immunity for Industrial Environments EN 61000-6-4; Emissions for Industrial Environments Electrical Safety European Community Directive: LV Directive 2014/35/EU Standards: EN 61010-1 RoHS European Community Directive:

RoHS Directive 2011/65/EU Cyber Security Designed to meet IEC 62443 Maritime DNV GL rules for classification – Ships, offshore units, and high speed and light craft ABS Rules for Condition of Classification, Part 1 l Steel Vessels Rules l Offshore Units and Structures.

相关文章
|
程序员
Qualcomm QXDM工具简介和log抓取
高通工具简介 QXDM 简介 QXDM 安装 QXDM 激活 QXDM 使用AT打开Diagnostic口 QXDM 配置 1 Message View Configuration Message Packets Log Packets Log PacketsO...
5725 0
|
8月前
|
存储 网络安全 虚拟化
window server2016 ISCSI存储程序对接华三CAS平台
该文档介绍了使用VMware 17 Pro搭建Windows Server 2016 64位的过程,并结合华三CAS平台设置ISCSI存储服务。首先,通过快速安装创建虚拟机,选择桌面版本。安装完成后,开启服务器管理器,拍摄快照备份。接着,添加1TB硬盘,格式化后,在服务器管理器中安装ISCSI角色和功能。配置ISCSI发起器,指定IP地址,并在CAS平台注册存储设备。最后,共享存储并格式化LUN,完成实验配置。
144 0
window server2016 ISCSI存储程序对接华三CAS平台
|
8月前
|
编解码 开发工具 vr&ar
RT-Thread 瑞萨 智能家居网络开发:RA6M3 HMI Board 以太网+GUI技术实践
RT-Thread 瑞萨 智能家居网络开发:RA6M3 HMI Board 以太网+GUI技术实践
273 4
|
8月前
|
物联网 Java 数据安全/隐私保护
App Inventor 2 低功耗蓝牙(BLE) 硬件接入、数据通信及IO控制
低功耗蓝牙(BLE)以低功耗、低成本、开发简便逐渐被广泛应用,本文主要介绍一款较为通用、价格低廉的BLE设备从零开始如何利用App Inventor 2开发一款自己专属的手机蓝牙App应用。 本文主要通过一款常见的BLE硬件接入控制,介绍硬件接入App Inventor 2 的通用方法,类似的硬件接入都是大同小异的。
390 1
|
传感器 编解码 监控
3500/42M 是由 Bently Nevada 开发的 Proximitor Seismic Monitor 组件
3500/42M 是由 Bently Nevada 开发的 Proximitor Seismic Monitor 组件
179 0
3500/42M 是由 Bently Nevada 开发的 Proximitor Seismic Monitor 组件
|
Android开发
Moto Z2 Force正式发布!史上最强模块化手机!
自从联想收购了摩托罗拉(MOTO)以后,整个摩托罗拉就开始走下坡路。
265 0
Moto Z2 Force正式发布!史上最强模块化手机!
|
弹性计算 缓存 应用服务中间件
一个netdisk storage backend app webos和增强的全功能网站云设想
本文关键字:利用网盘空间,network filesystem代替静态网站空间,做成静态网站的动态模块,利用v2ray,nginx给onedrive+onemanager做自动cdn,利用网盘代替函数计算
344 0
一个netdisk storage backend app webos和增强的全功能网站云设想
Felix&Paul为VR一体机Oculus Go推出《侏罗纪世界:蓝色》5K重制版
VR设备或许不再是少数爱好者的收藏物,而会成为广大普通消费人群都会去选择使用的生活必备品。
443 0
|
数据安全/隐私保护