Vmware虚拟机进入BIOS方法

简介:

在VMware里面如何进入BIOS是个头疼的问题,因为启动界面一闪而过(下 面两个图如果不设置bios.bootDelay,基本上很难抓到),即使你狂按F2或ESC键(ESC: 调整启动顺序;F2: 进入BIOS Setup) ,绝大部分都无法进入BIOS。因为VMware启动界面显示时间太短、系统无法识别按键而直接开启了系统。

clip_image001

clip_image002

研究了一下,发现VMware的配置文件.vmx可以控制这个过程, 网上提示有两种参数可以设置来解决这个问题:

    1. 加入一行:bios.forceSetupOnce = "TRUE" ;开机就自动进入BIOS!

       不过VMware启动后,会将该参数由TRUE变为FALSE,如果您还要继续使用BIOS,就再手动改成TRUE即可;

    2. 延长启动画面时间:bios.bootDelay = "10000";10000为10秒。

特意在Vmware上测试了一下,如下所示,找到服务器GETTESTLX的Vmware的配置文件,具体内容如下所示,在配置文件末尾配置上面两个参数都能顺利进入BIOS。

clip_image003

.encoding = "UTF-8"
config.version = "8"
virtualHW.version = "8"
nvram = "GETTESTLX.nvram"
pciBridge0.present = "TRUE"
svga.present = "TRUE"
pciBridge4.present = "TRUE"
pciBridge4.virtualDev = "pcieRootPort"
pciBridge4.functions = "8"
pciBridge5.present = "TRUE"
pciBridge5.virtualDev = "pcieRootPort"
pciBridge5.functions = "8"
pciBridge6.present = "TRUE"
pciBridge6.virtualDev = "pcieRootPort"
pciBridge6.functions = "8"
pciBridge7.present = "TRUE"
pciBridge7.virtualDev = "pcieRootPort"
pciBridge7.functions = "8"
vmci0.present = "TRUE"
hpet0.present = "TRUE"
displayName = "GETTESTLX"
extendedConfigFile = "GETTESTLX.vmxf"
virtualHW.productCompatibility = "hosted"
memSize = "1024"
scsi0.virtualDev = "lsilogic"
scsi0.present = "TRUE"
ide1:0.deviceType = "cdrom-image"
ide1:0.fileName = "/vmfs/volumes/4f38d1b9-9720c09c-38a5-782bcb6ee1e6/ISO/OracleLinux-R5-U7-Server-x86_64-dvd.iso"
ide1:0.present = "TRUE"
floppy0.startConnected = "FALSE"
floppy0.clientDevice = "TRUE"
floppy0.fileName = "vmware-null-remote-floppy"
ethernet0.virtualDev = "e1000"
ethernet0.networkName = "IP27"
ethernet0.addressType = "vpx"
ethernet0.generatedAddress = "00:50:56:b3:c0:f7"
ethernet0.present = "TRUE"
scsi0:0.deviceType = "scsi-hardDisk"
scsi0:0.fileName = "GETTESTLX.vmdk"
scsi0:0.present = "TRUE"
guestOS = "rhel5-64"
toolScripts.afterPowerOn = "TRUE"
toolScripts.afterResume = "TRUE"
toolScripts.beforeSuspend = "TRUE"
toolScripts.beforePowerOff = "TRUE"
uuid.bios = "42 33 d1 9c 71 9c 24 d8-82 e0 84 22 ae f7 e5 9a"
vc.uuid = "50 33 09 82 fa 29 14 fc-e0 4c 34 78 f6 56 a7 a2"
sched.scsi0:0.throughputCap = "off"
sched.swap.derivedName = "/vmfs/volumes/54e2da83-530edd90-a073-842b2b58e01d/GETTESTLX/GETTESTLX-a452f717.vswp"
uuid.location = "56 4d f0 82 ff e1 99 25-75 92 bc 2c 02 0a 59 af"
replay.supported = "FALSE"
replay.filename = ""
scsi0:0.redo = ""
pciBridge0.pciSlotNumber = "17"
pciBridge4.pciSlotNumber = "21"
pciBridge5.pciSlotNumber = "22"
pciBridge6.pciSlotNumber = "23"
pciBridge7.pciSlotNumber = "24"
scsi0.pciSlotNumber = "16"
ethernet0.pciSlotNumber = "32"
vmci0.pciSlotNumber = "33"
vmci0.id = "-1359485542"
hostCPUID.0 = "0000000b756e65476c65746e49656e69"
hostCPUID.1 = "000206c220200800029ee3ffbfebfbff"
hostCPUID.80000001 = "0000000000000000000000012c100800"
guestCPUID.0 = "0000000b756e65476c65746e49656e69"
guestCPUID.1 = "000206c200010800829822030fabfbff"
guestCPUID.80000001 = "00000000000000000000000128100800"
userCPUID.0 = "0000000b756e65476c65746e49656e69"
userCPUID.1 = "000206c220200800029822030fabfbff"
userCPUID.80000001 = "00000000000000000000000128100800"
evcCompatibilityMode = "FALSE"
vmotion.checkpointFBSize = "4194304"
cleanShutdown = "TRUE"
softPowerOff = "FALSE"
sched.scsi0:0.shares = "normal"
ide1:0.allowGuestConnectionControl = "TRUE"
tools.remindInstall = "TRUE"
相关文章
|
14天前
|
存储 SQL 数据库
虚拟化数据恢复—Vmware虚拟机误还原快照的数据恢复案例
虚拟化数据恢复环境: 一台虚拟机从物理机迁移到ESXI虚拟化平台,迁移完成后做了一个快照。虚拟机上运行了一个SQL Server数据库,记录了数年的数据。 ESXI虚拟化平台上有数十台虚拟机,EXSI虚拟化平台连接了一台EVA存储,所有的虚拟机都存放在EVA存储上。 虚拟化故障: 工组人员误操作将数年前迁移完成后做的快照还原了,也就意味着虚拟机状态还原到数年前,近几年数据都被删除了。 还原快照相当于删除数据,意味着部分存储空间会被释放。为了不让这部分释放的空间被重用,需要将连接到这台存储的所有虚拟机都关掉,需要将不能长时间宕机的虚拟机迁移到别的EXSI虚拟化平台上。
93 50
|
1月前
|
安全 虚拟化 数据中心
Xshell 连接 VMware虚拟机操作 截图和使用
Xshell 连接 VMware虚拟机操作 截图和使用
49 4
|
1月前
|
Linux 虚拟化
vmware虚拟机安装2024(超详细)
vmware虚拟机安装2024(超详细)
295 6
|
1月前
|
虚拟化 网络虚拟化 网络架构
虚拟机 VMware Workstation 16 PRO 的网络配置
虚拟机 VMware Workstation 16 PRO 的网络配置
|
2月前
|
存储 SQL 数据挖掘
虚拟化数据恢复—VMware虚拟机vmdk文件被误删除的数据恢复案例
虚拟化数据恢复环境: 某品牌服务器(部署VMware EXSI虚拟机)+同品牌存储(存放虚拟机文件)。 虚拟化故障: 意外断电导致服务器上某台虚拟机无法正常启动。查看虚拟机配置文件发现这台故障虚拟机除了磁盘文件以外其他配置文件全部丢失,xxx-flat.vmdk磁盘文件和xxx-000001-delta.vmdk快照文件还在。管理员联系VMware工程师寻求帮助。VMware工程师尝试新建一个虚拟机来解决故障,但发现ESXi存储空间不足。于是将故障虚拟机下的xxx-flat.vmdk磁盘文件删除,然后重建一个虚拟机并且分配固定大小的虚拟磁盘。
|
虚拟化 数据安全/隐私保护 Linux
|
5月前
|
Unix Linux 虚拟化
虚拟机VMware知识积累
虚拟机VMware知识积累
|
3月前
|
测试技术 Linux 虚拟化
iOS自动化测试方案(五):保姆级VMware虚拟机安装MacOS
详细的VMware虚拟机安装macOS Big Sur的保姆级教程,包括下载VMware和macOS镜像、图解安装步骤和遇到问题时的解决方案,旨在帮助读者顺利搭建macOS虚拟机环境。
146 3